Effective fire protection starts with the technology

Reliable fire protection is the result of well thought-out technology. In buildings, it is not just a matter of detection and extinguishing in an emergency. The functionality, monitoring and maintenance of the entire sprinkler system must also be guaranteed at all times. This requires control and monitoring units or fittings for permanent pressure monitoring or safe maintenance. Proven components from the TRI-MATIC range perform essential tasks in the field of sprinkler technology. In building fire protection, selected valves ensure safe and smooth operation.

Safe maintenance and effective flushing with the fire tap

The fire tap with fixed coupling and dummy coupling is a central component in sprinkler systems that enables the targeted flushing, cleaning and filling of entire or individual pipe sections. With this component, individual sections can be taken out of service quickly and safely during maintenance, conversion or expansion without jeopardising the overall fire protection in the building - ideal for regular maintenance cycles or servicing.

To the TRI-FIRE VALVE in detail

Keep a constant eye on the pressure with pressure gauges with drag or marker pointers

Pressure gauges with a drag indicator or marker pointer are indispensable for permanent pressure monitoring in the fire protection system. Pressure gauges with drag indicators show the maximum pressure reached, enable traceability and facilitate troubleshooting and regular inspections. Pressure gauges with a marker pointer ensure that the minimum system pressure is monitored and that the system is refilled to the correct pressure in the event of a pressure loss. Whether with two brand pointers, coloured segments, logo or company name: The pressure gauges can be customised.

To the pressure gauges

Practical ball valve with vent and fitting for hose connection

Safe operation of the system is ensured by a ball valve with integrated venting and fitting. Venting is particularly important when refilling or after maintenance work in order to remove air from the system and prevent malfunctions. When using the ball valve upstream of the pressure gauge, the measuring device can also be disconnected from the sprinkler system as soon as the pressure has been read. The remaining water between the pressure gauge and the ball valve can be drained cleanly via the fitting with hose connection.

To the TRI-BALL SUPER in detail

Draining and flushing of branch lines with the Tappy ball valve

With the Tappy ball valve, branch lines can be quickly and easily flushed hygienically or emptied, flushed or refilled during commissioning and maintenance. By simply opening the tap, stagnant water is drained in a targeted manner, effectively preventing deposits or stagnation. This contributes significantly to the longevity, operational safety and hygiene of the entire system. The Tappy ball valve is an ideal component for service water installations and sprinkler systems.

Safe zone butterfly valves with position monitoring

For the maintenance of water sprinkler systems, the Association of Cantonal Fire Insurers (VKF) prescribes the use of safe zone shut-off dampers where the handle cannot be removed when the valve is closed. This ensures maximum safety and clear signalling that the line is closed. The integrated position monitoring enables the damper status to be checked, which significantly improves operational safety.

The right combination of functional technology and robust design ensures effective fire protection, ease of maintenance and operational safety. Rely on our proven monitoring units and fittings such as pressure gauges, ball valves or butterfly valves for maximum safety in everyday life and in an emergency. Contact our experts for personalised advice.

Request advice